Testing Equipment
| We bring forth a precision engineered range of testing equipment that include digital UPS scanners/digital meters, high voltage breakdown testers, UPS annunciators, digital variacs, insulation resistance testers, variable frequency voltage/current source and others. Designed using cutting edge technology, these testing equipment are known for their application specific designs, reliable functions and durable performance. Further, our range is stringently made in compliance with relevant industrial norms. |
Digital UPS Scanners/Digital Meters
This product is exclusively designed for UPS industry to meet their need of monitoring different parameters like O/p voltage, O/p current, Frequency, Battery voltage, Battery current with common display at economy.
| Dimension |
(96 x 96 x 50 ) mm |
| Panel Cutout |
( 92 x 92 ) mm |
| Power |
5 V, Com. - 5 V |
| Operating Temp. |
Ambient to 65oC |
| Parameter |
Range |
Accuracy |
Resolution |
| AC Voltage |
0 to 450 V AC |
( 0.75 % rdg 2 dgt) |
1 Volt |
| AC Current |
As Per CT ratio |
( 0.75 % rdg 2 dgt) |
0.1 Amp. |
| Frequency |
48 to 52 Hz |
( 2 dgt) |
0.1 Hz |
| DC Voltage |
0 to 500 V DC |
( 0.75 % rdg 2 dgt) |
1 volt |
| DC Current |
As per shunt ratio |
( 0.75 % rdg 2 dgt) |
0.1 Amp. |
Add to Enquiry Basket |
 |
High Voltage Breakdown Testers
Our high voltage break down testers is accurate for testing of any high voltage component. They test vacuum tubes, high voltage capacitors, vacuum relays, etc. To use them, they require just hook up component and adjusting the high voltage with panel variac, then the current can easily be read on panel meter.
| Digital Meter |
Accuracy for kV : 1.5% FS, for mA : 0.1% |
| Timer |
Positions : 3 Sec, 12 Sec, 30 Sec, 1 Min, 2 Min, 5 Min |
| Power Requirement |
230 V AC, /- 10%, 50/60 Hz |
| Type |
Maximum Test Voltage (kv) |
Typical Leakage currents (mA) |
Application (Industry sector) |
| AC HV Tester |
5,10 |
20,100,350 |
Transformer, Control Panels, UPS, Stabilizer etc. |
| DC HV Tester |
5,10 |
20,100,350 |
Capacitor |
| AC/DC HV Tester |
5,10 |
20,100,350 |
Transformer, Control Panels, UPS, Stabilizer etc. |
Add to Enquiry Basket |
 |
UPS Annunciators
This product is exclusively designed for UPS industry to meet their need of monitoring different parameters like O/p voltage, O/p current, frequency, battery voltage, battery current with common display at economy. It has LCD display which indicates and also user can program the trip levels of overload, over voltage etc.
| Parameter |
Ranges |
Accuracy |
| I/P AC Voltage |
230V or 440V |
(0.75% rdg 1dgt) |
| I/P AC Current |
As per CT ratio |
(1.5%rdg 1dgt) |
| I/P AC Frequency |
47 to 53 Hz |
1 dgt |
| O/P AC Voltage |
230 V or 440 V |
(0.75% rdg 1dgt) |
| O/P AC Current |
As per CT ratio |
(1.5% rdg 1dgt) |
| O/P Frequency |
47 to 53 Hz |
1dgt |
| Battery Voltage |
0 to 500 VDC |
(0.75% rdg 1dgt) |
| Battery Current |
As per Shunt ratio |
(0.75% rdg 1dgt) |
Add to Enquiry Basket |
 |
Digital Variacs
Digital Variac is used for determining load and line regulation of Power supplies, SMPS, UPS etc. It saves time of making connection of voltmeter and Ammeter.
| Digital Meter : (With Select Switch) |
For Voltage and Current |
| Output Voltage |
Range : 270 V AC |
| Accuracy : 0.75 % |
| Current |
Range : 2.0 Amp AC, 5.0 Amp. AC |
| Accuracy : 0.75 % |
| Dimensions |
( 130 x 240 x 160 ) mm For 2 Amp. |
| ( 180 x 300 x 160 ) mm For 5 Amp |
Add to Enquiry Basket |
 |
Insulation Resistance Testers
½Our insulation resistance testers are necessary in electrical industry like transformer, pumps, control panels etc. They are also useful in component industries like capacitors, relays, contactors etc.
| IR Measurement Range | 0 to 200 M §Ù | | Test Voltage | 500 V/1000 V DC (As per requirement) | | Meter | 3½ digit LED | | Accuracy of Display | 0.75 % FS | | Accuracy of Test Voltage | 2 % @100 M §Ù burden |
Add to Enquiry Basket |
 |
Variable Frequency Voltage/Current Source
We manufacturer these sources for the benefit of Industry who manufacture transformers of different frequencies. Magnetic material and ferrites etc. They are also useful in testing of frequency relays.
| Output Voltage Range | 0 to 440 V (for Voltage Source) | | Output Current Source | 0 to 100 A (for Current Source) | | Frequency Range | 40 to 1000 Hz | | Total Harmonic Distortion | Less than 2.5% for Voltage & Current Source | | Stability | 0.1% (After Warm-up) | | Output Power | Up to 500 VA or as per customer requirement | | Digital Meters | 3½ digit Voltage/Current, 4 digit Frequency | | Protection | Overload and short circuit | | Operating Temperature | 25±10ºC | | Line / Load Regulation | 1.5% for (230±10%) |
Add to Enquiry Basket |
 |
Electronic Load
We are manufacturer and exporter of high quality electronic load, which are used by battery manufacturers for assessing AH capacity of battery. Also it is very useful for testing of DC Powers supplies and SMPS.
| ypical Load Range |
0 - 20 A (settable by multi turn potentiometer)* |
| Load Current Regulation |
/- 0.1 % (for a change of battery voltage form No load voltage to end voltage level) |
| Line Regulation |
/- 0.1 % (for /- 10% change in mains supply) |
| Power Requirement |
230 V AC /- 10% 50Hz |
| Metering |
3 Digit Volt. Amp meter with selector switch indicates battery voltage and current or separate Volt and Ammeter. |
Add to Enquiry Basket |
 |
Watt Meter Calibrators
Our watt meter calibrator simulates AC Watts i.e. Power. It has 4 digit LED display and clearly labeled front panel controls.
| Input Power |
230V AC, 50/60 HZ |
| AC Voltage ( 50 Hz) Range |
0 to 500V |
| AC Current (50 Hz) Range |
0 to 10 Amp |
| Power Factor Range |
0.6 to unity ( Lag & Lead) |
| Wattmeter Range |
0 to 5000 Watt( Multiplication of V, A and PF) |
| Accuracy( at 250C, RH< 70 %) |
|
| AC V |
0.15% |
| Amp |
0.15% |
| Power Factor |
0.20% |
| Watt |
0.35% |
Add to Enquiry Basket |
 |
|