View Enquiry Basket
Resistance Testers
We manufacture wide range of resistance testers for various electric and electronic products. These testers are extensively in the market due to their reliability, precision and accuracy. All our testers are subjected to stringent quality check to ensure their high quality standards. Our testers are easy to use and aids in increasing the production rate of the clients. Manufactured using high grade raw material, these testers are durable and maintenance free. We can customize our testers on the basis of the specifications provided by our clients.
Salient features:
- Application Specific Design
- Accurate Readings
- Digital display Unit
- Maintenance Free
- Easy to Use and Install
- Wide Range Available
|
DC Electronic Load

 | We design and engineer accurate electronic load. The electronic load offered by us can test the loads ranging from 0 A to 20 A. We can design load of very high ratings. These load works on 230 V AC ±10% 50Hz. Electronic load is very good tool to assess AH capacity of Battery. Further we can add features like Cutting off the discharge test as battery reaches to End Voltage and Timer(time totaliser) to count total discharge time on customers’ request.
Technical Specifications:
- Typical Load Range: 0 - 20 A (settable by multi turn potentiometer)*
- Load Current Regulation: ±0.05 % (for a change of battery voltage form no load voltage to end voltage level)
- Line Regulation: ±0.05 % (for ±10% change in mains supply)
- Power Requirement: 230 V AC ±10% 50Hz
- Metering: 3 Digit Voltage Amp meter with selector switch indicates battery voltage and current or separate Volt and Ammeter.
- Time Totaliser(Optional)
- Press to set end voltage for battery discharging
| Parameter | Range | Resolution | Accuracy | | DC Volt | 15 V | 0.01 V | 0.5% rdg ± 2 digits | | DC Current | 20 A | 0.01 A | 0.5% rdg ± 2 digits | * Note: Electronic Loads of higher ratings can also be designed to suit customer requirement.
Add to Enquiry Basket |
Ground/Earth Continuity Tester
 | The ground/earth continuity tester offered by us works on test current of sinusoidal waveform. The typical test current severity is 30A meters to indicate test current voltage drop across ground path and m Ω before starting the test.
Technical Specifications:
- Power: 230V AC, ± 10 %, 50 Hz
- Resistance Measurement Range: 0 to 200 milli Ohm
- Test Current: 30 A ± 1% AC
- Open Circuit Voltage: 8V, AC
- Current Waveform: Sinusoidal
- Acceptable setting: by press to set switch and potentiometer, using digital milli Ohm meter
- Programmable Timer: 1 to 60 sec
- Metering: 3 ½ digit Digital V, A and milli Ohm meter
- Indication Accuracy: V: 1.5% of reading, A: 1.5% of reading, m Ω: 1.5% of reading± 5dgt
- Accuracy of trip resistance: ± 5 m Ω
- Indications: Trip, Test On, Test Off
- Output test: curren through high current wire and Earth pin of 3 pin socket
- Accessory: High Current Crocodile wire / Test Probe
- Method of measurement: Passing a constant AC current (30A) and measuring a voltage drop across the resistance to be measured
Add to Enquiry Basket |
High Voltage Breakdown Tester

 | We offer precision engineered high voltage breakdown tester that are used for checking the adequacy of Insulation. These are used for testing breakdown voltage for Transformer, Control Panels, UPS, Stabilizer, and Capacitor. Insulation between the live and earth or between two different sections of live parts, this insulation is required to be tested at high voltage values recommend by applicable relevant standards. The standard specifications for various electrical apparatus specifies power frequency voltage withstand tests at different levels depending upon the working voltage of electrical apparatus. The maximum test voltage ranges from 5 to 10 KV.
Technical Specifications:
- Digital Meter: Accuracy for kV : 1.5% FS, for mA : 0.5%
- Timer Positions: 3 Sec , 12 Sec, 30 Sec, 1 Min, 2 Min, 5 Min
- Power Requirement: 230 V AC, +/- 10% , 50/60 Hz
| Type | Maximum Test Voltage (kv) | Typical Leakage currents (mA) | Application (Industry sector) | | AC HV Tester | 5, 10, 80 | 20,100,350 | Transformer, Control Panels, UPS, Stabilizer etc. | | DC HV Tester | 5, 10, 40 | 20,100,350 | Capacitor | | AC/DC HV Tester | 5, 10, 20 | 20,100,350 | Transformer, Control Panels, UPS, Stabilizer etc. |
Features:
- Audio and Visual Alarm when HV ON and Off
- Test ON and OFF Switch to start and Interrupt Test
- Unique Data Hold facility to hold Breakdown Voltage Data
- Precise Trip Current Setting or Press to Set Switch for Leakage Current
- Inbuilt timer with Selector Switch
Add to Enquiry Basket |
Insulation Resistance Tester

 | Insulation Resistance Tester measures the insulation resistance value at different DC test voltage models with fixed test voltage as well as with variable test voltage. The resistance in measurement ranges in excess of 100 M Ω are also available.
Technical Specifications:
| IR Measurement Range | 0 to 2000 | | Test Voltage | 500 V/1000 V DC (for models with fixed test voltages) For models with variable test voltage-1 to 1000 VDC | | Meter | 31/2 digit LED | | Accuracy of Display | 0.5 % FS | | Accuracy of Test Voltage | ± 2 % @100 M Ω burden |
Add to Enquiry Basket |
Linear Transmitter Simulator

 | We offer a qualitative range of linear transmitter simulators, that are extensively demanded in the market owing to their reliability, precision and accuracy. Manufactured using advanced technology, these are stringently checked on quality parameters to ensure high quality standards. Further, our range is available in different specifications to meet the diverse requirements of clients. We offer quality approved Linear Transmitter Simulator having following technical specification: | Input Power | 24 V ± 10% DC C single phase | | DC Current Range | 4 to 20mA (with percentage selector switch) | | | 0%= 4mA, 25%= 8mA, 50%= 12mA,75%= 16mA, 100%= 20mA | | Accuracy of settings | 0.15 % | | | With Transmitter ON indication by LED |
Add to Enquiry Basket |
Variable Voltage/Current Variable Frequency Tester

 | Variable voltage/current variable frequency source is used to simulate mains conditions of different countries. Also it is used for verifying frequency response of power devices, frequency relays and components. Variable current variable frequency source are used for checking current transformers.
Technical Specifications:
| Output Voltage Range: Single Phase or 3 Phase | 0 to 440 V (for Voltage Source) | | Output Current Source | 0 to 100 A (for Current Source) | | Output Wattage | 12 kVA | | Frequency Range | 40 to 1000 Hz | | Total Harmonic Distortion | Less than 1.25% for Precision Voltage and Current Source. 3.5% for Power sources | | Stability | 0.1% (After Warm-up) | | Output Power | Up to 500 VA or as per customer requirement | | Digital Meters | 3½ digit Voltage/Current 4 digit Frequency | | Protection | Overload and short circuit | | Operating Temperature | 25 ±100C | | Line / Load Regulation | 0.5 % for (230 ±10%) |
Add to Enquiry Basket |
Transistor, Zener, and Diode Tester

 | We manufacture transistors and zener diode tester which are highly durable and are used for various testing and measuring purposes. They are completely reliable and are demanded in the national and international markets for various electronic and electrical testing purposes.
| Transistors | pnp or npn for hfe, IC saturation current, reverse leakage current. | | Diodes | Forward drop, reverse breakdown voltage | | Zener Diodes | Forward drop and zener voltage Forward drop @maximum test current 10A
| | Ranges | Reverse / Breakdown voltage up to 1000V Reverse leakage current up to 1 micro A |
Add to Enquiry Basket |
Transistors/Zener Diode Testers
 | We manufacture transistors and zener diode tester which are highly durable and are used for various testing and measuring purposes. They are completely reliable and are deamnded in the national and international markets for various electronic and electrical testing purposes.
| Transistors | pnp or npn for hfe, IC saturation current, reverse leakage current. | | Diodes | Forward drop, reverse breakdown voltage | | Zener Diodes | Forward drop and zener voltage | | Ranges | Forward drop @maximum test current 10A, Reverse / Breakdown voltage up to 1000V Reverse leakage current up to 1 micro A |
Add to Enquiry Basket |
|